$186.28
Add to Cart
HVW48005G Shindengen 250W HV Series Power Supply - 48V/5A
SPECIFICATIONS
INPUT
Voltage 85 - 264 VAC (continuous)
Frequency 47 - 63 Hz
Current
Full Load 120V - 3.1A (RMS)
240V - 1.6A (RMS)
Inrush 120V - 15A
240V - 30A
OUTPUT
Regulation
Total ±5.0%
Drift ±0.3% (for 8 hours after 10 min. warm-up)
Temp. Coefficient ±0.01%/°C max.
Ripple & Noise (peak-to-peak)
1.50V max.
(measured at 25°C with a bandwidth of 50 MHz)
Hold-up Time 10 mS min.
(measured at nominal input voltage, full
load, 25°C)
Converter Topology Forward Converter
Operating Frequency 400 KHz
PROTECTION
Overvoltage All models are protected against overvoltage.
Control circuit is preset so output voltage does
not exceed the following values:
Output V 24 48
OVP 32 60
Overload All models are protected against overload. The
control circuit has a foldback characteristic with
the knee set at 110% of full-rated load.
Recovery is automatic after removal of the fault.
FEATURES
n Meets International Safety & Conducted Noise Specifications
-UL1950 Recognized
-CSA 22.2 No. 234 Certified
-IEC950/EN60950 (TUV Certified)
-Independently Tested to FCC Level A,
VDE level A, VCCI Class 1
-CE
n Wide Range Input Voltage
n MTBF > 300,000 Hours, Field Failure Rate < 0.01%
n Remote ON/OFF; Power Fail
n Power Factor Corrected 0.99 (typ.)
n Overtemperature, Overload and Overvoltage Alarm
n Fan-Cooled
n Parallel Operation
AUXILIARY FEATURES
Operating Indication LED
EPO Emergency power off
Remote ON/OFF Output voltage ON - closed contacts +RC, -RC
Output voltage OFF - open contacts +RC, -RC
Thermal Protection Automatic shutdown under overtemperature
condition.
AC Power Fail Provided.
Power Alarm Provided.
Parallel Operation Units with like output voltage rating can be
operated in parallel regardless of current rating.
INSULATION
All models meet the requirements of UL1950, CSA 22.2 No. 234, and
EN60950 for Input-to-Chassis, Input-to-Output, Output-to-Chassis and
Leakage Current specifications. See Engineering Section.
ENVIRONMENT
Operating Temp. –10 to +50°C at full load.
Operating Humidity 20 - 90% relative humidity (non-condensing)
Storage Temp. –25 to +75°C
Storage Humidity 10 - 95% relative humidity (non-condensing)
Shock < 10G
Vibration 4.5G, 10 - 55 Hz, 0.75 mm amplitude
(non-operating)
250 Watt HV Series
INPUT
Voltage 85 - 264 VAC (continuous)
Frequency 47 - 63 Hz
Current
Full Load 120V - 3.1A (RMS)
240V - 1.6A (RMS)
Inrush 120V - 15A
240V - 30A
OUTPUT
Regulation
Total ±5.0%
Drift ±0.3% (for 8 hours after 10 min. warm-up)
Temp. Coefficient ±0.01%/°C max.
Ripple & Noise (peak-to-peak)
1.50V max.
(measured at 25°C with a bandwidth of 50 MHz)
Hold-up Time 10 mS min.
(measured at nominal input voltage, full
load, 25°C)
Converter Topology Forward Converter
Operating Frequency 400 KHz
PROTECTION
Overvoltage All models are protected against overvoltage.
Control circuit is preset so output voltage does
not exceed the following values:
Output V 24 48
OVP 32 60
Overload All models are protected against overload. The
control circuit has a foldback characteristic with
the knee set at 110% of full-rated load.
Recovery is automatic after removal of the fault.
FEATURES
n Meets International Safety & Conducted Noise Specifications
-UL1950 Recognized
-CSA 22.2 No. 234 Certified
-IEC950/EN60950 (TUV Certified)
-Independently Tested to FCC Level A,
VDE level A, VCCI Class 1
-CE
n Wide Range Input Voltage
n MTBF > 300,000 Hours, Field Failure Rate < 0.01%
n Remote ON/OFF; Power Fail
n Power Factor Corrected 0.99 (typ.)
n Overtemperature, Overload and Overvoltage Alarm
n Fan-Cooled
n Parallel Operation
AUXILIARY FEATURES
Operating Indication LED
EPO Emergency power off
Remote ON/OFF Output voltage ON - closed contacts +RC, -RC
Output voltage OFF - open contacts +RC, -RC
Thermal Protection Automatic shutdown under overtemperature
condition.
AC Power Fail Provided.
Power Alarm Provided.
Parallel Operation Units with like output voltage rating can be
operated in parallel regardless of current rating.
INSULATION
All models meet the requirements of UL1950, CSA 22.2 No. 234, and
EN60950 for Input-to-Chassis, Input-to-Output, Output-to-Chassis and
Leakage Current specifications. See Engineering Section.
ENVIRONMENT
Operating Temp. –10 to +50°C at full load.
Operating Humidity 20 - 90% relative humidity (non-condensing)
Storage Temp. –25 to +75°C
Storage Humidity 10 - 95% relative humidity (non-condensing)
Shock < 10G
Vibration 4.5G, 10 - 55 Hz, 0.75 mm amplitude
(non-operating)
250 Watt HV Series