• CATEGORIES
    • All Categories
    • Antiques
    • Art
    • Automotive
    • Baby
    • Beauty & Fragrances
    • Books & Magazines
    • Business & Industrial
    • Cameras & Photo
    • Cell Phones, PDAs & Accessories
    • Clothing & Shoes
    • Collectibles
    • Computers & Networking
    • Crafts
    • Electronics
    • Entertainment Memorabilia
    • Flowers & Gifts
    • Glass & Pottery
    • Health & Personal Care
    • Home & Garden
    • Jewelry & Watches
    • Misc
    • Movies & DVDs
    • Music
    • Office Supplies
    • Real Estate
    • Services
    • Sex Stuff
    • Sports & Outdoors
    • Sports Memorabilia
    • Tools & Hardware
    • Toys, Games & Hobbies
    • Video Games
  • COMMUNITY
  • FAQ
  • SELL
  • AU
    • US
    • UK
    • AU
  • Cart
eCrater
  • Sign Up
  • Login
  • Home >
  • All Categories >
  • Electronics(56080)


$41.76 Add to Cart

9-28VDC Conventional Manual Call Point Fire Push In Pull Down Emergency Alarm

9-28VDC Conventional Manual Call Point Fire Push In Pull Down Emergency Alarm

More than 10 available

Details

Shipping: Australia: free (more destinations)

Sales Tax: check

Condition: Brand new

Returns: 30 days, buyer pays return shipping (more)

*The store has not been updated recently. You may want to contact the merchant to confirm the availability of the product.

  • 9-28VDC Conventional Manual Call Point Fire Push In Pull Down Emergency Alarm
  • 9-28VDC Conventional Manual Call Point Fire Push In Pull Down Emergency Alarm
  • 9-28VDC Conventional Manual Call Point Fire Push In Pull Down Emergency Alarm
  • 9-28VDC Conventional Manual Call Point Fire Push In Pull Down Emergency Alarm
Tweet    
  • Description
The HC102 conventional manual call point designed for conventional fire alarm system for reporting fire or emergence condition by its PUSH IN/PULL DOWN handle latches
Key lock available
Operating voltage range: 9-28VDC Volts
Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position , the word" ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag.
Note: All wiring must conform to applicable local codes, ordinances, and regulations.
Operation:
The manual call points provide a textured finger-hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking people.
Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position , the word" ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag.
Resetting the station is simple: insert the key, twist one quarter-turn, then open the station's front cover, causing the spring-loaded operation handle to return to its original position. The alarm switch can then be reset to its normal(non-alarm) position manually(by hand) or by closing the station's front cover, which automatically resets the switch.

Loop design and wiring:
The fire alarm control panel Zone wire can be connected to terminal loop(+), loop(-) unpolarized wire.
If the manual call point is in the end of the zone wire, a 5.6K resistance should be connected to terminal loop(+),loop(-).

Installation:
Note: All wiring must conform to applicable local codes, ordinances, and regulations.

Mounting indoor wall
Attach mounting base to wall at 1.5 meter's high
Connect field wiring to terminals
To attach product to mounting base
Secure product by tightening the one mounting screws in the front of the product housing.

Specifications:
Operating voltage range: 9-28VDC Volts
Alarm resistance: 470ohm/1W
Operating humidity range: 10% to 93% relative humidity, non-condensing
Operating temperature range: -10℃ to 50℃ (14F to 122F)
Dimensions: 140x104x45mm(LxWxH)
Net Weight: 220g

Package:
1 x Fire alarm call point
2 x Keys
1 x English manual
... [Full Description]

You may also be interested in:

  • $8.00
    SONY FH-9 Original Service manual

    SONY FH-9 Original Service manual

    cmjharrison
  • $16.79
    Denon AVR-X4000 ,AVR-S900CI Ver.9 Network AV Receiver Service Manual PDF (SBTDN1801)

    Denon AVR-X4000 ,AVR-S900CI Ver.9 Network AV Receiver Service Manual PDF (SBTDN1801)

    sbt-servicemanuals
  • $16.79
    Denon DBP-1611UD Ver.9 Service Manual PDF SBTDN2116

    Denon DBP-1611UD Ver.9 Service Manual PDF SBTDN2116

    sbt-servicemanuals
  • $16.79
    Denon AVR-4311CI ,AVR-4311 Ver.1 Surround Receiver Service Manual PDF (SBTDN1460)

    Denon AVR-4311CI ,AVR-4311 Ver.1 Surround Receiver Service Manual PDF (SBTDN1460)

    sbt-servicemanuals
  • $13.99
    JBL GT5-A3001 Rev.0 Power Amplifier Service Manual PDF (SBTJBL4257)

    JBL GT5-A3001 Rev.0 Power Amplifier Service Manual PDF (SBTJBL4257)

    sbt-servicemanuals
  • $16.79
    Samsung UN65D8000XF Service Manual

    Samsung UN65D8000XF Service Manual

    sbt-servicemanuals
  • $188.85
    Apple Airpods 2nd Gen!!! 9.1/10

    Apple Airpods 2nd Gen!!! 9.1/10

    thewizardofodd
  • $16.79
    Denon  HEOS 1 HS2 Ver.5 Wireless Speaker Service Manual PDF (SBTDN1265)

    Denon HEOS 1 HS2 Ver.5 Wireless Speaker Service Manual PDF (SBTDN1265)

    sbt-servicemanuals
  • $13.99
    Denon AVR-1601 ,AVR-681 Surround Receiver Service Manual PDF (SBTDN1391)

    Denon AVR-1601 ,AVR-681 Surround Receiver Service Manual PDF (SBTDN1391)

    sbt-servicemanuals
  • $11.19
    JBL GTH400 Power Amplifier Service Manual PDF (SBTJBL4329)

    JBL GTH400 Power Amplifier Service Manual PDF (SBTJBL4329)

    sbt-servicemanuals

Title of Image

Seller Information

Seller

gate-hardware-and-equipments 0half/5 Stars
  • Contact Seller
  • -81.62%, 184 sales
‹ ›
View Store

Location

  • US, FL

Payment

  • Personal Check

Additional Info

  • Terms and Policy
  • Contact Info
  • © 2026
  • ·
  • eCRATER
  • ·
  • Get your free online store
Last Updated: 19 Jun 2024 09:37:50 PDT
  • about
  • ·
  • terms
  • ·
  • privacy
  • ·
  • dmca
  • ·
  • contact
  • ·
  • news
Follow Us