$356.82
Add to Cart
Endress+Hauser Liquiphant T PMC131-A11F1A1S Pressure transmitters Free shipping
7 available
Details
Shipping: Australia: free (more destinations)
Condition: Brand new
*The store has not been updated recently. You may want to contact the merchant to confirm the availability of the product.
Endress+Hauser (Datasheet can be offered by mail if you need)
Pressure transmitters for absolute and gauge pressure measurement
Cerabar T PMC131 ( we have stock for Model No: PMC131-A11F1A1S, PMC131-A11F1D38 with same price)
•Reliable with long-term stability
•Vacuum and overload stability
•Will withstand corrosion and abrasion
•Simple assembly
•Integrated 4 to 20 mA electronics
Product:
Liquids, vapors and gases
Measuring cell:
Dry (oil-free) ceramic cell
Overload stability:
Up to factor 40
Measuring range (limits):
0 to 1.5 psi (100 mbar),
0 to 600 psi (40 bar)
Product temperature:
-4 to +212°F
(-20 to +100 °C)
Accuracy:
< 0.5 %
Application
The Cerabar T PMC131 measures absolute and gauge pressures in liquids, vapours and gases using a highly accurate, overload resilient ceramic capacitance sensor, which offers long-term stability and is resistant to corrosion and abrasion.
Function
The measured pressure causes a slight deflection of the sensor diaphragm. The change in proportion to pressure is measured and is converted into a 4 to 20 mA output signal. The pressure transmitter is available with either a DIN 43650/ISO 4400 plug or cable entry for connection to an amplifier supply system such as a RN221N power supply.
Application Example
pls see fourth picture of product.
Technical data
General
•Output signal
4 to 20 mA/two-wire
•Max. load Ra
Ra [Ω] ≤ (Ub -11 V)/0.02 A
Accuracy
•Analog output
Reference conditions according to DIN IEC 770; ≤ 0.5 % FS1) (linearity including hysteresis and repeatability)
•Effect of ambient
temperature
In relation to nominal value; -20 to +85 °C
zero point: typ. < 1.5 % of URL;
range: typ. < 1 % of URL
•Long-term stability
< 0.15 % FS1) per annum
•Response time T90
20 ms
Operating conditions
•Material temperature
-4 to +212°F (-20 to +100 °C)
•Ambient temperature
-4 to +185°F (-20 to +85 °C)
•Storage temperature
-58 to 212°F (-50 to +100 °C)
•Climate class
4K4H according DIN EN 60721-3
•Protection
IP 65 plug
IP 68 with cable entry (5 m or 25 m (16 ft or 82 ft))
•Vibration stability
4M5 according to DIN EN 60721-3
•EMC
Interference emission as per EN 61326
electrical device class B;
interference immunity as per EN 61326
appendix A (industrial use)
Materials of construction
•Process connection
G ½ A according to DIN 16288,
G ½ A according to ISO 228
hole Ø 6 mm or 11 mm (0.24” or 0.43”)
•Materials in contact with medium
Process connection and housing: 1.4301
Seal (internal location): FPM (Viton)
•Process diaphragm
Al2O3 (aluminium oxide ceramic)
•Electrical connection
4-pole plug connection according to ISO 4400 with cable connection M16 or 5/25 m (16/82 ft) fixed cable
Power supply Ub
•Supply voltage
Ub 11 to 30 V DC at 5 % wave
Special Versions
•Devices for oxygen applications (up to 435 psi (30 bar)) on request
Approval
•GL-Approval available on demand
1) FS = Full Scale = Measuring range
Pressure transmitters for absolute and gauge pressure measurement
Cerabar T PMC131 ( we have stock for Model No: PMC131-A11F1A1S, PMC131-A11F1D38 with same price)
•Reliable with long-term stability
•Vacuum and overload stability
•Will withstand corrosion and abrasion
•Simple assembly
•Integrated 4 to 20 mA electronics
Product:
Liquids, vapors and gases
Measuring cell:
Dry (oil-free) ceramic cell
Overload stability:
Up to factor 40
Measuring range (limits):
0 to 1.5 psi (100 mbar),
0 to 600 psi (40 bar)
Product temperature:
-4 to +212°F
(-20 to +100 °C)
Accuracy:
< 0.5 %
Application
The Cerabar T PMC131 measures absolute and gauge pressures in liquids, vapours and gases using a highly accurate, overload resilient ceramic capacitance sensor, which offers long-term stability and is resistant to corrosion and abrasion.
Function
The measured pressure causes a slight deflection of the sensor diaphragm. The change in proportion to pressure is measured and is converted into a 4 to 20 mA output signal. The pressure transmitter is available with either a DIN 43650/ISO 4400 plug or cable entry for connection to an amplifier supply system such as a RN221N power supply.
Application Example
pls see fourth picture of product.
Technical data
General
•Output signal
4 to 20 mA/two-wire
•Max. load Ra
Ra [Ω] ≤ (Ub -11 V)/0.02 A
Accuracy
•Analog output
Reference conditions according to DIN IEC 770; ≤ 0.5 % FS1) (linearity including hysteresis and repeatability)
•Effect of ambient
temperature
In relation to nominal value; -20 to +85 °C
zero point: typ. < 1.5 % of URL;
range: typ. < 1 % of URL
•Long-term stability
< 0.15 % FS1) per annum
•Response time T90
20 ms
Operating conditions
•Material temperature
-4 to +212°F (-20 to +100 °C)
•Ambient temperature
-4 to +185°F (-20 to +85 °C)
•Storage temperature
-58 to 212°F (-50 to +100 °C)
•Climate class
4K4H according DIN EN 60721-3
•Protection
IP 65 plug
IP 68 with cable entry (5 m or 25 m (16 ft or 82 ft))
•Vibration stability
4M5 according to DIN EN 60721-3
•EMC
Interference emission as per EN 61326
electrical device class B;
interference immunity as per EN 61326
appendix A (industrial use)
Materials of construction
•Process connection
G ½ A according to DIN 16288,
G ½ A according to ISO 228
hole Ø 6 mm or 11 mm (0.24” or 0.43”)
•Materials in contact with medium
Process connection and housing: 1.4301
Seal (internal location): FPM (Viton)
•Process diaphragm
Al2O3 (aluminium oxide ceramic)
•Electrical connection
4-pole plug connection according to ISO 4400 with cable connection M16 or 5/25 m (16/82 ft) fixed cable
Power supply Ub
•Supply voltage
Ub 11 to 30 V DC at 5 % wave
Special Versions
•Devices for oxygen applications (up to 435 psi (30 bar)) on request
Approval
•GL-Approval available on demand
1) FS = Full Scale = Measuring range





CN, Guangdong